glass microscope slides (plain, corning) Search Results


90
Corning Life Sciences glass microscope slides plain
The angular distribution of fluorescence intensity of sulforhodamine 101 (S101) spin-coated with polyvinyl alcohol (PVA) on silvered <t>microscope</t> slide. The silver layer was 50 nm thick (EMF, Ithaca, NY). The spin-coated sample was prepared from 0.5% PVA solution which results in the thickness of near 15 nm. About half of the entire emission is coupled to the cone. The photograph on the right was taken at about 47° from the distance of about 1 m.
Glass Microscope Slides Plain, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pmc02737392-39-0-6?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
glass microscope slides plain - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences custom glass slides corning 75 × plain microscope slides
The angular distribution of fluorescence intensity of sulforhodamine 101 (S101) spin-coated with polyvinyl alcohol (PVA) on silvered <t>microscope</t> slide. The silver layer was 50 nm thick (EMF, Ithaca, NY). The spin-coated sample was prepared from 0.5% PVA solution which results in the thickness of near 15 nm. About half of the entire emission is coupled to the cone. The photograph on the right was taken at about 47° from the distance of about 1 m.
Custom Glass Slides Corning 75 × Plain Microscope Slides, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pmc02856313-104-5-8?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
custom glass slides corning 75 × plain microscope slides - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences plain glass microscope slides with a 22 × no. 1.5 coverglass
The angular distribution of fluorescence intensity of sulforhodamine 101 (S101) spin-coated with polyvinyl alcohol (PVA) on silvered <t>microscope</t> slide. The silver layer was 50 nm thick (EMF, Ithaca, NY). The spin-coated sample was prepared from 0.5% PVA solution which results in the thickness of near 15 nm. About half of the entire emission is coupled to the cone. The photograph on the right was taken at about 47° from the distance of about 1 m.
Plain Glass Microscope Slides With A 22 × No. 1.5 Coverglass, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pmc02672522-221-20-21?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
plain glass microscope slides with a 22 × no. 1.5 coverglass - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences plain glass microscope slides corning frosted end, one side, 75
Materials Used for the Pressurized Coverslipping and HIAR.
Plain Glass Microscope Slides Corning Frosted End, One Side, 75, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pmc06542147-0-0-5?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
plain glass microscope slides corning frosted end, one side, 75 - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences hydrophobic glass microscope slides corning plain
Materials Used for the Pressurized Coverslipping and HIAR.
Hydrophobic Glass Microscope Slides Corning Plain, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pm15836001-235-0-4?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
hydrophobic glass microscope slides corning plain - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences plain, precleaned microscope glass slides (75)
Materials Used for the Pressurized Coverslipping and HIAR.
Plain, Precleaned Microscope Glass Slides (75), supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pm25621905-35-2-0?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
plain, precleaned microscope glass slides (75) - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences soda-lime plain microscope glass slides corning 2947-75 × 25 × 3
Materials Used for the Pressurized Coverslipping and HIAR.
Soda Lime Plain Microscope Glass Slides Corning 2947 75 × 25 × 3, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/10__1016_slash_j__nanoso__2022__100856-50-5-10?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
soda-lime plain microscope glass slides corning 2947-75 × 25 × 3 - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences plain glass microscope slides for confocal microscopy
Materials Used for the Pressurized Coverslipping and HIAR.
Plain Glass Microscope Slides For Confocal Microscopy, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pm27571169-136-88-96?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
plain glass microscope slides for confocal microscopy - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences plain, pre-cleaned microscope glass slides 75
Materials Used for the Pressurized Coverslipping and HIAR.
Plain, Pre Cleaned Microscope Glass Slides 75, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pm26695740-144-2-0?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
plain, pre-cleaned microscope glass slides 75 - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences glass substrates corning plain microscope slides
Materials Used for the Pressurized Coverslipping and HIAR.
Glass Substrates Corning Plain Microscope Slides, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/10__1007_slash_s13391___013___3284___y-56-0-2?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
glass substrates corning plain microscope slides - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Corning Life Sciences glass slide corning 75 × plain microscope slides
Materials Used for the Pressurized Coverslipping and HIAR.
Glass Slide Corning 75 × Plain Microscope Slides, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+microscope+slides+%28plain%2C+corning%29/pm40641433-270-5-7?v=Corning+Life+Sciences
Average 90 stars, based on 1 article reviews
glass slide corning 75 × plain microscope slides - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

Image Search Results


The angular distribution of fluorescence intensity of sulforhodamine 101 (S101) spin-coated with polyvinyl alcohol (PVA) on silvered microscope slide. The silver layer was 50 nm thick (EMF, Ithaca, NY). The spin-coated sample was prepared from 0.5% PVA solution which results in the thickness of near 15 nm. About half of the entire emission is coupled to the cone. The photograph on the right was taken at about 47° from the distance of about 1 m.

Journal:

Article Title: Directional surface plasmon-coupled emission: a new method for high sensitivity detection

doi: 10.1016/S0006-291X(03)01214-2

Figure Lengend Snippet: The angular distribution of fluorescence intensity of sulforhodamine 101 (S101) spin-coated with polyvinyl alcohol (PVA) on silvered microscope slide. The silver layer was 50 nm thick (EMF, Ithaca, NY). The spin-coated sample was prepared from 0.5% PVA solution which results in the thickness of near 15 nm. About half of the entire emission is coupled to the cone. The photograph on the right was taken at about 47° from the distance of about 1 m.

Article Snippet: Sample preparation Glass microscope slides (plain, Corning) were covered with a continuous 50 nm thick silver film, which was vapor deposited by EMF (Ithaca, NY).

Techniques: Fluorescence, Microscopy

Materials Used for the Pressurized Coverslipping and HIAR.

Journal: Journal of Histochemistry and Cytochemistry

Article Title: Mechanical Compression of Coverslipped Tissue Sections During Heat-induced Antigen Retrieval Prevents Section Detachment and Preserves Tissue Morphology

doi: 10.1369/0022155419826940

Figure Lengend Snippet: Materials Used for the Pressurized Coverslipping and HIAR.

Article Snippet: Plain glass microscope slides (e.g., Corning frosted end, one side, 75 × 25 mm) , 3 , Ted Pella Inc.; 26005.

Techniques: Microscopy, Transferring, Staining

Step-by-step instructions for pressure coverslipping of mounted tissue sections for heat-induced antigen retrieval treatment. The detailed protocol, (A) to (I), is given in the “Materials and Methods” section. Inset in (E), schematic illustration of a pressure-coverslipped slide: (1) microscope slide with mounted tissue section, (2) Teflon sheet, (3) second microscope slide, and (4) plastic tubing clamp.

Journal: Journal of Histochemistry and Cytochemistry

Article Title: Mechanical Compression of Coverslipped Tissue Sections During Heat-induced Antigen Retrieval Prevents Section Detachment and Preserves Tissue Morphology

doi: 10.1369/0022155419826940

Figure Lengend Snippet: Step-by-step instructions for pressure coverslipping of mounted tissue sections for heat-induced antigen retrieval treatment. The detailed protocol, (A) to (I), is given in the “Materials and Methods” section. Inset in (E), schematic illustration of a pressure-coverslipped slide: (1) microscope slide with mounted tissue section, (2) Teflon sheet, (3) second microscope slide, and (4) plastic tubing clamp.

Article Snippet: Plain glass microscope slides (e.g., Corning frosted end, one side, 75 × 25 mm) , 3 , Ted Pella Inc.; 26005.

Techniques: Microscopy

Reattaching partially detached tissue sections using pressure coverslipping and HIAR. (A and A′) Three paraffin-embedded mouse kidney sections were mounted on a microscope slide. After paraffin removal and rehydration, two sections were still properly attached to the slide, whereas the third section was almost completely detached. (A′) shows the same slide as in (A) at a different angle. (B and B′) After HIAR treatment using pressure coverslipping, all three sections were properly attached to the slide. (B′) and (B) are at different angles. (C–E) The three sections from (A–B′) were immunolabeled with an antibody against the mineralocorticoid receptor (MR). In all three sections, specific nuclear labeling in distinct segments of the tubular epithelium that belong to the aldosterone-sensitive distal nephron was observed. In the reattached section (E and E′), artifactual DAB reaction product was observed at the margin of the section. Scale bars: (A–B′), 400 μm; (C–E′), 100 μm. Abbreviation: HIAR, heat-induced antigen retrieval.

Journal: Journal of Histochemistry and Cytochemistry

Article Title: Mechanical Compression of Coverslipped Tissue Sections During Heat-induced Antigen Retrieval Prevents Section Detachment and Preserves Tissue Morphology

doi: 10.1369/0022155419826940

Figure Lengend Snippet: Reattaching partially detached tissue sections using pressure coverslipping and HIAR. (A and A′) Three paraffin-embedded mouse kidney sections were mounted on a microscope slide. After paraffin removal and rehydration, two sections were still properly attached to the slide, whereas the third section was almost completely detached. (A′) shows the same slide as in (A) at a different angle. (B and B′) After HIAR treatment using pressure coverslipping, all three sections were properly attached to the slide. (B′) and (B) are at different angles. (C–E) The three sections from (A–B′) were immunolabeled with an antibody against the mineralocorticoid receptor (MR). In all three sections, specific nuclear labeling in distinct segments of the tubular epithelium that belong to the aldosterone-sensitive distal nephron was observed. In the reattached section (E and E′), artifactual DAB reaction product was observed at the margin of the section. Scale bars: (A–B′), 400 μm; (C–E′), 100 μm. Abbreviation: HIAR, heat-induced antigen retrieval.

Article Snippet: Plain glass microscope slides (e.g., Corning frosted end, one side, 75 × 25 mm) , 3 , Ted Pella Inc.; 26005.

Techniques: Microscopy, Immunolabeling, Labeling

Pressure coverslipping during HIAR enables a distinctly more homogeneous immunolabeling of large tissue sections. (A–B″) A celloidin-embedded section of human tonsil tissue was mounted on a microscope slide (A). Overview (B) and higher magnifications (B′ and B″) of the same section after immunolabeling for PCNA and hematoxylin staining. Only a few weakly PCNA-labeled cells were observed in the lymphoid follicles. (C–D″) After HIAR without pressure coverslipping, disseminated focal detachment of the tissue section occurred—arrowheads and arrows in (D). These areas exhibited a more intense PCNA-immunolabeling and hematoxylin staining compared with adherent regions of the section—arrowhead in (D′), which resulted in nonhomogeneous labeling of the entire tissue section. (E–F″) Using HIAR with pressure coverslipping, the entire tissue section remained adherent to the slide (F). An intense and homogeneous immunolabeling for PCNA and hematoxylin staining was achieved (F′ and F″). Scale bars: (A, B, C, D, E, and F), 5 mm; (B′, B″, D′, D″, F′, and F″), 100 μm. Abbreviations: HIAR, heat-induced antigen retrieval; PCNA, proliferating cell nuclear antigen.

Journal: Journal of Histochemistry and Cytochemistry

Article Title: Mechanical Compression of Coverslipped Tissue Sections During Heat-induced Antigen Retrieval Prevents Section Detachment and Preserves Tissue Morphology

doi: 10.1369/0022155419826940

Figure Lengend Snippet: Pressure coverslipping during HIAR enables a distinctly more homogeneous immunolabeling of large tissue sections. (A–B″) A celloidin-embedded section of human tonsil tissue was mounted on a microscope slide (A). Overview (B) and higher magnifications (B′ and B″) of the same section after immunolabeling for PCNA and hematoxylin staining. Only a few weakly PCNA-labeled cells were observed in the lymphoid follicles. (C–D″) After HIAR without pressure coverslipping, disseminated focal detachment of the tissue section occurred—arrowheads and arrows in (D). These areas exhibited a more intense PCNA-immunolabeling and hematoxylin staining compared with adherent regions of the section—arrowhead in (D′), which resulted in nonhomogeneous labeling of the entire tissue section. (E–F″) Using HIAR with pressure coverslipping, the entire tissue section remained adherent to the slide (F). An intense and homogeneous immunolabeling for PCNA and hematoxylin staining was achieved (F′ and F″). Scale bars: (A, B, C, D, E, and F), 5 mm; (B′, B″, D′, D″, F′, and F″), 100 μm. Abbreviations: HIAR, heat-induced antigen retrieval; PCNA, proliferating cell nuclear antigen.

Article Snippet: Plain glass microscope slides (e.g., Corning frosted end, one side, 75 × 25 mm) , 3 , Ted Pella Inc.; 26005.

Techniques: Immunolabeling, Microscopy, Staining, Labeling

Pressure coverslipping during HIAR preserves the delicate morphology of decalcified, celloidin-embedded human temporal bone (TB) sections. (A–B″) A celloidin-embedded human TB section after mounting on a microscope slide (A). Hematoxylin staining reveals the trabecular bony structure of the mastoid (left part of the section), cross-sections through the cavities of the middle and inner ear (middle part of the section), and the compact bone of the petrous apex (right part of the section). In particular, the delicate membranous structures of the cochlea—auditory portion of the inner ear (B′)—are vulnerable to the mechanical stress that occurs during histological processing and immunolabeling of the tissue. Without HIAR, no immunolabeling for the serum and glucocorticoid-regulated kinase 1 (SGK1) is observed in the organ of Corti (B″). (C–D′) After HIAR without pressure coverslipping, the tissue section almost completely detached from the slide (C and D). The delicate structures of the cochlea were almost completely disrupted (D′). The section could no longer be used for immunohistochemical labeling. (E–F″) After HIAR with pressure coverslipping, the section remained properly attached to the microscope slide (E). The morphology of all structures within the TB section was preserved (F), including the delicate architecture of the cochlea (F′). Immunolabeling for SGK1 showed nuclear and cytoplasmic signals in most supporting cells of the organ of Corti (F″). Scale bars: (A, B, C D, E, and F), 5 mm; (B′, D′, and F′), 1 mm; (B″ and F″), 100 μm. Abbreviation: HIAR, heat-induced antigen retrieval.

Journal: Journal of Histochemistry and Cytochemistry

Article Title: Mechanical Compression of Coverslipped Tissue Sections During Heat-induced Antigen Retrieval Prevents Section Detachment and Preserves Tissue Morphology

doi: 10.1369/0022155419826940

Figure Lengend Snippet: Pressure coverslipping during HIAR preserves the delicate morphology of decalcified, celloidin-embedded human temporal bone (TB) sections. (A–B″) A celloidin-embedded human TB section after mounting on a microscope slide (A). Hematoxylin staining reveals the trabecular bony structure of the mastoid (left part of the section), cross-sections through the cavities of the middle and inner ear (middle part of the section), and the compact bone of the petrous apex (right part of the section). In particular, the delicate membranous structures of the cochlea—auditory portion of the inner ear (B′)—are vulnerable to the mechanical stress that occurs during histological processing and immunolabeling of the tissue. Without HIAR, no immunolabeling for the serum and glucocorticoid-regulated kinase 1 (SGK1) is observed in the organ of Corti (B″). (C–D′) After HIAR without pressure coverslipping, the tissue section almost completely detached from the slide (C and D). The delicate structures of the cochlea were almost completely disrupted (D′). The section could no longer be used for immunohistochemical labeling. (E–F″) After HIAR with pressure coverslipping, the section remained properly attached to the microscope slide (E). The morphology of all structures within the TB section was preserved (F), including the delicate architecture of the cochlea (F′). Immunolabeling for SGK1 showed nuclear and cytoplasmic signals in most supporting cells of the organ of Corti (F″). Scale bars: (A, B, C D, E, and F), 5 mm; (B′, D′, and F′), 1 mm; (B″ and F″), 100 μm. Abbreviation: HIAR, heat-induced antigen retrieval.

Article Snippet: Plain glass microscope slides (e.g., Corning frosted end, one side, 75 × 25 mm) , 3 , Ted Pella Inc.; 26005.

Techniques: Microscopy, Staining, Immunolabeling, Immunohistochemical staining, Labeling